Changes between Initial Version and Version 6 of Ticket #2432
- Timestamp:
- Sep 21, 2026, 5:37:41 PM (3 weeks ago)
Legend:
- Unmodified
- Added
- Removed
- Modified
-
Ticket #2432
- Property Summary spudec_process_control can read beyond the end of a packet. → spudec_process_control can read beyond the end of a packet, now with fix!
-
Ticket #2432 – Description
initial v6 7 7 I have just seen a problem where a packet is 2020 bytes long. 8 8 9 At byte 2019 there is a control command `0x02` (stop display). There is no `0xff` after the `0x02`, because that's beyond the end of the packet.9 At byte 2019 there is a control command `0x02` (stop display). There is no `0xff` after the `0x02`, because that's beyond the end of the fragment. 10 10 11 11 But spudec_process_control continues on reading control commands, and encounters invalid control types.